What causes urinary tract infections due to catheters?

Catheters play an important role in urinary management. They can be used for drainage, urine volume observation, urine testing, bladder irrigation, and are also helpful in assisting diagnosis. However, improper operation of catheters can also cause urinary tract infections, seriously affecting the patient's physical health and quality of life.

There are many reasons why a urinary catheter can cause urinary tract infection, mainly including the following aspects:

1. Lax aseptic operation: During the catheterization process, if the aseptic operation specifications are not strictly followed, such as skin preparation is not performed, the urethral opening is not thoroughly disinfected, or the disinfection range is not large enough, exogenous bacteria may be brought into the urethra and bladder, thereby causing urinary tract infection.

2. Long-term indwelling of the urinary catheter: Generally speaking, the indwelling time of the urinary catheter should be controlled within 3-7 days. If it needs to be indwelled for a long time, the urinary catheter should be replaced every 7-10 days. Long-term indwelling of the urinary catheter not only increases the risk of urinary tract infection, but also may cause obstruction of urine secretion glands, thereby causing urinary tract infections such as acute urethritis. In addition, if the urinary catheter is indwelled for more than two weeks, the probability of infection will increase significantly.

3. Improper catheter care: After indwelling catheterization, nursing measures such as bladder flushing and urethral disinfection are required. If these care measures are not carried out in a timely and effective manner, bacteria may grow around the catheter, leading to urinary tract infection.

4. Damage to the tightness of the urinary tract: After the indwelling catheter, the tightness of the urinary tract is damaged, making it easier for bacteria to invade the urinary tract. At the same time, if the urine drainage system is not well sealed, or the urine bag is higher than the bladder, contaminated urine may flow back into the bladder, causing urinary tract infection.

What causes urinary tract infections due to catheters? 1

5. Catheter irritation and friction: During the indwelling process, the catheter will irritate and rub the urethral mucosa, which may reduce the defense ability of the urethral mucosa, making it easier for bacteria to invade and cause infection.

6. Biofilm infection: Substances in urine may deposit on the surface of the urinary catheter to form a thin film that helps bacteria colonize and resist antibiotic treatment. After bacteria attach to the surface of the urinary catheter, they secrete extracellular matrix to form a biofilm, further exacerbating the infection.

7. Encrustation: When urease-producing bacteria adhere to the urinary catheter, they gradually form a catheter encrustation. This encrustation not only causes poor drainage and obstruction of the urinary catheter, but may also aggravate the progression of catheter-related infections.

In summary, there are many reasons why urinary tract infections are caused by urinary catheters, including lax aseptic operation, prolonged indwelling of urinary catheters, improper care of urinary catheters, damage to urinary tract tightness, irritation and friction of urinary catheters, biofilm infection, and crusting. In order to prevent the occurrence of urinary tract infections, medical staff should strictly abide by aseptic operation specifications, reasonably control the indwelling time of urinary catheters, strengthen urinary catheter care, maintain urinary tract tightness, and pay close attention to changes in the patient's condition.

prev
The secret weapon of the ICU: endotracheal tube that can automatically prolong life
Types of urinary catheters and main product parameters
suivant
Recommandé pour vous
pas de données
Entrer en contact avec nous
Heures d'ouverture
L'équipe marketing et l'équipe technique sont nos principaux atouts pour bâtir notre réputation et notre partenariat à long terme avec nos partenaires/clients étrangers, avec une communication efficace et des préventes fiables. & support technique après-vente. Depuis les années 2010, nous avons coopéré avec plus de 500 entreprises à travers le monde, les marchés occupant principalement l'Asie...
Contact avec nous

Zhongshan Centurial Medical Technology Co., Ltd

Adresse de l'entreprise : C502, 5e étage, rue n°3 Hongtu, route Hongji, district de Shiqi, 528400, ville de Zhongshan, province du Guangdong, Chine.


E-mail de l'entreprise: info@centurial.com.cn

Tél. entreprise : +86 760 8878 8984


Personne de contact : Mme. Linnéa LlN

E-mail de contact: linnealin@centurial.com.cn

Contacter mob./Wechat/Whatsapp/Skvpe : +86 17666371196

Droits d'auteur © 2024 Centurial| -https://www.centurial.com.cn/ Plan du site
Customer service
detect